Heat pump sizing in Birmingham
- Design outdoor temperature (estimate)
- −3.7 °C
- median of each winter’s lowest two-day mean, 1991–2020
- Degree days (base 20/15)
- 3,019 Kd
- mean 2016–2025, kelvin-days a year · 1991–2020: 3,212 Kd
- Heating days a year
- 262
Weather station WELLESBOURNE, 36.2 km away, 47 m above sea level.
Heat loss and heat pump from your fuel use
Heat loss = heat demand × (20 °C − design temperature) ÷ (24 h × degree days). Electricity = heat demand ÷ SCOP, spread over the months by their degree days. Assumptions you can change: boiler efficiency 90 %, SCOP 3.5 (air-to-water heat pump; higher with underfloor heating, lower with high flow temperatures). Hot water is part of the gas use and treated like space heating. Enter your own electricity tariff to see the cost. Enter your electricity unit rate to see the running cost.